AK900-0007G3 Three Phase 0.75kw Motor Drive 380v 3HP VFD Frequency Inverter

AK900-0007G3 Three Phase 0.75kw Motor Drive 380v 3HP VFD Frequency Inverter

Regular price 0 دينار و الدفع عند الاستلام
Regular price Sale price 0 دينار و الدفع عند الاستلام
Sale Sold out
Tax included.

Model

AK900-0007G1

AK900-0015 G1

AK900-0022 G1

AK900-0040 G1

AK900-0055 G1

AK900-0007G3

AK900-0015G3

AK900-0022G3

AK900-0040G3

AK900-0055G3 

Power Range


Single phase AC 220V ac (-15%~+30%) 0.75~22KW, 3 phase AC 380V ac (-15%~+30%) 0.75~45KW

Output Frequency  Range

0~600Hz

Control Mode

V/F Control, Sensor less Vector Control

Starting Torque

0.5Hz/150%(SVC), 1Hz/150%(V/F);

Communication Port

RS-485, which support MODBUS protocol (optional)

Vibration

Less than 5.9m/s

Fault Protection

protect from over current, over voltage, under voltage, over temperature, phase failure, over load etc.

 

Item

 

Specifications

 

 

 

 

 

 

 

 

 

 

 

 

 

Basic Function

 

Over load capability


G type:150% rated current 60s;180% rated current 3s

Torque boost


Auto torque boost function; Manual torque boost 0.1%~30.0%

V/F curve

Linear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2)

V/F separation


2 ways: separation and semi-separation

 

 

Acc./dec curve


Straight line or S curve acceleration and deceleration mode,

Four kinds of acceleration and deceleration time. Acceleration and deceleration time range from 0.0s to 6500.0s

 

DC braking

DC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s to 36.0s

Brake current value:0%-100%

 

Jog control

Jog frequency range:0.00Hz~50.00Hz;

Jog acceleration/deceleration:0.0s~6500.0s.

Simple PLC

It can realize at maximum of 16 segments speed

 

 

 

 

 

 

 

 

 

    Basic Function

Multiple segment speed running

Running via the built-in PLC or control terminal.

Built-in PID


It is easy to realize process-controlled closed loop control system.

Auto voltage regulation (AVR)

It can keep constant output voltage automatically in the case of change of network voltage.

Over-voltage/current stall control

It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running
process.

Quick current limit

Minimize the over-current fault, protect normal operation of the AC Drive.

Torque limit & control

"Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop
vector mode can realize the torque control.

 

 

Personalized Function

Instantaneous stop non-stop

When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep
running in a short period of time.

Rapid current limit

To avoid AC Drive frequent over-current fault.

Timing control

Timing control function :set time range 0Min~6500.0Min.

Keyboard Operation

Keyboard potentiometer


Equipped with keyboard potentiometer or coding potentiometer.

 

Keyboard Operation

 

Protection function

It can implement power-on motor short-circuit detection, input /output phase loss protection, over current protection, over
voltage protection, under voltage protection, overheating protection and overload protection.

 

 

 

 

 

 

Environment


Using place

Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt.

Altitude


Below 1000m

Ambient temperature

-10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃)

Humidity

Less than 95%RH,without condensing

Vibration

Less than 5.9m/s (0.6g)

View full details