AK900-0022 G1 Single Phase 2.2kw Motor Drive 220v 1HP VFD Frequency Inverter
AK900-0022 G1 Single Phase 2.2kw Motor Drive 220v 1HP VFD Frequency Inverter
Couldn't load pickup availability
Model |
AK900-0007G1 AK900-0015 G1 AK900-0022 G1 AK900-0040 G1 AK900-0055 G1 AK900-0007G3 AK900-0015G3 AK900-0022G3 AK900-0040G3 AK900-0055G3 |
|
Power Range |
|
|
Output Frequency Range |
0~600Hz |
|
Control Mode |
V/F Control, Sensor less Vector Control |
|
Starting Torque |
0.5Hz/150%(SVC), 1Hz/150%(V/F); |
|
Communication Port |
RS-485, which support MODBUS protocol (optional) |
|
Vibration |
Less than 5.9m/s |
|
Fault Protection |
protect from over current, over voltage, under voltage, over temperature, phase failure, over load etc. |
|
Item |
Specifications |
|
Basic Function |
Over load capability |
|
Torque boost |
|
|
V/F curve |
Linear V/F, multi-point V/F and square V/F curve(power of 1.2,1.4,1.6,1.8,2) |
|
V/F separation |
|
|
Acc./dec curve |
|
|
Four kinds of acceleration and deceleration time. Acceleration and deceleration time range from 0.0s to 6500.0s |
||
DC braking |
DC braking frequency:0.00Hz to maximum frequency. Braking time:0.0s to 36.0s |
|
Brake current value:0%-100% |
||
Jog control |
Jog frequency range:0.00Hz~50.00Hz; |
|
Jog acceleration/deceleration:0.0s~6500.0s. |
||
Simple PLC |
It can realize at maximum of 16 segments speed |
|
Basic Function |
Multiple segment speed running |
Running via the built-in PLC or control terminal. |
Built-in PID |
|
|
Auto voltage regulation (AVR) |
It can keep constant output voltage automatically in the case of change of network voltage. |
|
Over-voltage/current stall control |
It can limit the running voltage/current automatically and prevent frequent over-voltage/current tripping during the running |
|
Quick current limit |
Minimize the over-current fault, protect normal operation of the AC Drive. |
|
Torque limit & control |
"Excavators" characteristics, automatically limit torque during operation, prevent frequent over-current tripping. Closed loop |
|
Personalized Function |
Instantaneous stop non-stop |
When instantaneous power off, voltage reduction is compensated through load feedback energy, which could make AC Drive keep |
Rapid current limit |
To avoid AC Drive frequent over-current fault. |
|
Timing control |
Timing control function :set time range 0Min~6500.0Min. |
|
Keyboard Operation |
Keyboard potentiometer |
|
Keyboard Operation |
Protection function |
It can implement power-on motor short-circuit detection, input /output phase loss protection, over current protection, over |
Environment |
|
Indoor, and be free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapor, drip or salt. |
Altitude |
|
|
Ambient temperature |
-10 ℃ to +40 ℃ (Derating use when under ambient temperature of 40 ℃ to 50 ℃) |
|
Humidity |
Less than 95%RH,without condensing |
|
Vibration |
Less than 5.9m/s (0.6g) |